Chapter 4 _______________________________________________________________ Installation
VAISALA_______________________________________________________________________ 95
Leaf Wetness Sensor
Installation Procedure
Leaf Wetness Sensor is delivered with an installation hardware kit and
a sensor cable.
Initial Check
You may test the sensor before you install it. The instructions below
provide a description of the suggested quick test procedure.
1. Connect the signal cable to an available connector at a data logger.
2. Configure the sensor with the particular software.
3. Drop or spray water onto the sensor and make sure the reading
changes.
Mounting to a Wooden Surface
To mount the sensor against a wooden surface, secure the sensor to the
surface using wood screws (see Figure 83 on page 95).
0105-070
Figure 83 Mounting QLW101 to a Wooden Surface