Vaisala HMP60 Handbuch

Stöbern Sie online oder laden Sie Handbuch nach Messen, Testen & Steuern Vaisala HMP60 herunter. Vaisala HMP60 Product manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 26
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HMP60 Temperature and
Relative Humidity Probe
Revision: 7/12
Copyright © 1995-2012
Campbell Scientific, Inc.
Seitenansicht 0
1 2 3 4 5 6 ... 25 26

Inhaltsverzeichnis

Seite 1 - Relative Humidity Probe

HMP60 Temperature andRelative Humidity ProbeRevision: 7/12Copyright © 1995-2012Campbell Scientific, Inc.

Seite 2

HMP60 Temperature and Relative Humidity Probe FIGURE 4-3. HMP60 and 41303-5A Radiation Shield on a CM202 Crossarm Mounting Clamp FIGURE 4-4. HM

Seite 3 - Warranty

HMP60 Temperature and Relative Humidity Probe 4.2 Step 2 — Use SCWin Short Cut to Program Datalogger and Generate Wiring Diagram The simplest method

Seite 4 - Assistance

HMP60 Temperature and Relative Humidity Probe 3. Select HMP50/HMP60 Temperature and Relative Humidity Sensor then click the right arrow to add it to

Seite 5 - HMP60 Table of Contents

HMP60 Temperature and Relative Humidity Probe 5. Choose the outputs for the AirTC and RH and then select finish. 6. Wire according to the wiring d

Seite 6 - Figures

HMP60 Temperature and Relative Humidity Probe TABLE 5-1. Recommended Lead Lengths 2 m Height Atop a tripod or tower via a 2 ft crossarm such as the

Seite 7 - Humidity Probe

HMP60 Temperature and Relative Humidity Probe Probe Body Diameter: 1.2 cm (0.47 in) Filter: 0.2 μm Teflon membrane Filter Diameter: 1.2 cm (0.47 in)

Seite 8 - 4. Quickstart

HMP60 Temperature and Relative Humidity Probe 7. Installation 7.1 Siting Sensors should be located over an open level area at least 9 m (EPA) in dia

Seite 9

HMP60 Temperature and Relative Humidity Probe Black Temperature Signal White Relative Humidity Signal Blue Signal & Power Reference Br

Seite 10

HMP60 Temperature and Relative Humidity Probe The temperature and relative humidity signals from the HMP60 are measured using two single-ended analog

Seite 11 - Generate Wiring Diagram

HMP60 Temperature and Relative Humidity Probe 7.4.2 Example for CR10X ;Measure the HMP60 temperature. ; 01: Volt (SE) (P1) 1: 1 Reps 2: 5 25

Seite 13 - 5. Overview

HMP60 Temperature and Relative Humidity Probe reference and power ground are connected to ground at the datalogger. The signal reference/power ground

Seite 14 - 6. Specifications

HMP60 Temperature and Relative Humidity Probe VaporPressure() instruction to calculate vapor pressure from temperature and relative humidity measureme

Seite 15 - 6.1 Temperature Sensor

HMP60 Temperature and Relative Humidity Probe 7.6.2 Sample CR10(X) Program that Computes Vapor Pressure and Saturation Vapor Pressure ;Measure the HM

Seite 16 - 7. Installation

HMP60 Temperature and Relative Humidity Probe 8. Maintenance The HMP60 Probe requires minimal maintenance. Check monthly to make sure the radiation

Seite 17 - 7.4 Programming

HMP60 Temperature and Relative Humidity Probe 18 3. Rinse the RH chip or dispose of the old RH chip. 4. Hold the sides of the rinsed or new chip and

Seite 19 - 7.5 Long Lead Lengths

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Seite 20 - 7.6 Absolute Humidity

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Seite 21

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Seite 22

HMP60 Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to

Seite 23 - 8. Maintenance

HMP60 Table of Contents ii Figures 4-1. HMP60 as shipped... 3 4-2. HM

Seite 24 - 10. References

HMP60 Temperature and Relative Humidity Probe 1. Introduction The HMP60 probe measures temperature for the range of -40° to 60°C, and relative humidi

Seite 25

HMP60 Temperature and Relative Humidity Probe 4. Quickstart 4.1 Step 1 — Mount the Probe Review Section 7, Installation for complete instructions.

Seite 26

HMP60 Temperature and Relative Humidity Probe Yellow Shipping Cap (remove before installation)FIGURE 4-1. HMP60 as shipped FIGURE 4-2. HMP60 and 4

Kommentare zu diesen Handbüchern

Keine Kommentare