User's Guide ______________________________________________________________________
122 __________________________________________________________________M210630EN-B
Giving Commands
When you have established the connection, you can use the commands
described in Table 20 on page 156 to communicate with MAWS.
Commands are text strings sent from the PC or terminal to MAWS.
To open the connection, give the open command. To close the terminal
connection, give the close command. Logging is not affected unless it
is stopped using the logstop command. In the closed mode, the serial
line will be available for report sending.
Most of the commands can be used both for setting a value for a
parameter and viewing the set value of a parameter.
Type help to get a list of the available commands. Each command must
be entered using the correct syntax. You do not have to memorize
complex commands since you can view a help text that shows the
correct syntax at any time. Simply type help and the command name.
NOTE
Both open and close commands have to be typed exactly correct
before they can be executed. This means, you can not use the
BACKSPACE key to correct your typing. Simply retype the command
and press ENTER to give the command again.
Table 12 Interpreting Help Texts (the Correct Syntax)
Generic
Representation
Example Note
Use the
parameter name.
warnings [clear] To see the warnings, type:
warnings
Parameters shown
in [ ] can be left out.
To remove warnings, type:
warnings clear
Replace
parameter
symbols with
values.
time [HH MM SS] [YY MM DD] To see current time, type:
time
To set new time, type e.g.:
time 15 45 00
To set new time and date,
e.g.: time 15 45 00 03 06 18
loggo <group_id> Parameters shown
in < > cannot be left
out.