Chapter 5 ________________________________________________________________ Operation
VAISALA______________________________________________________________________ 131
particular sensor. To calibrate other listed sensors, enter the gain of
the measurement, that is, the slope of the conversion curve.
After you have changed the value(s), click the Save button in the tab to
write the new values to MAWS.
NOTE
You can do either offset or gain calibration at a time. When you enter
a new value in the Value or Cal. Factor field, the other parameter will
be expressed as N/A until you save your changes. Note also that
entering a new value in the Value field, for example when performing
offset calibration, will reset the gain to 1.000.
NOTE
New sensor calibration values are taken into use after resetting
MAWS, for example, with the RESET command.