User's Guide ______________________________________________________________________
108 __________________________________________________________________M210630EN-B
Using Compass and Reference Point
With MAWS running, monitor the instant wind direction in the reports
sent through the serial line.
0201-034
Figure 101 Aligning Wind Vane
1. The wind sensor cable must be connected both to the sensor and to
the Wind connector.
2. The mounting piece (2) must be placed on top of the tube and the
sensor must be attached to the mounting piece with the plastic
collar (3).
3. Choose a known wind direction reference point on the horizon with
the help of a compass.
4. Point the nose of the vane at the reference point.
5. Hold the vane in position and slowly rotate the mounting piece
until the wind direction shows a proper value.
6. Secure the mounting piece to the mast by tightening the mounting
screw (4).