Chapter 5 ________________________________________________________________ Operation
VAISALA______________________________________________________________________ 127
0406-034
Figure 114 Setup Management View: Static Parameters Tab
The list under the Static Parameters tab shows all the static
parameters, including the preset ones. Refer to Figure 114 on page 127.
The user editable entries are listed in bold. The Default column shows
the default value for each parameter.
To create a new static parameter, proceed as follows:
1. In the Static Parameters tab, click Add.
2. Give a name for the parameter. The name may consist of characters
A...Z, a...z, 0...9, and _. No spaces are allowed.
3. Select a type for the parameter. The possible options, Number
(float), Number (int), or Text, will appear by double-clicking the
bold text in the Type column. Selecting the type will determine
how the parameter is used. A text parameter, for example, cannot
be used as calculation input.
NOTE
The default value is written to the logger memory only when the static
parameter does not have an existing value. For example, if the sname
parameter already has the value MAWS1 and a new setup is generated
with sname = MAWS2, the existing sname value (MAWS1) is
preserved.