User's Guide ______________________________________________________________________
188 __________________________________________________________________M210630EN-B
Determining MAWS Operation Mode
You can watch the status LED to determine the MAWS operation
mode. The LED is located on the MAWS logger board and it is visible
through the logger cover.
Establishing Terminal Connection
All MAWS software aided troubleshooting is performed using the
service terminal connection. Some of the operations can be executed
semiautomatically by the MAWS Terminal software, some require
entering the commands manually.
To connect your computer to a MAWS serial port, proceed as follows:
1. Start the MAWS Terminal program on your PC.
2. Set the communication parameters: 9600, N, 8, 1.
3. Give the command open (if the connection is not already open).
Figure 147 on page 189 shows the pin order for the terminal connector.
Table 24 Determining Operation Mode by LED Flashing
LED Flashing Interval Operation Mode Note
All the time MAWS has been reset
but setup has not been
examined yet.
Once per 5 seconds Setup is running.
Once per 10 seconds Blank boot or
configuration cannot be
run.
Quickly 2 times Setup is running but
there are warnings.
Interval determined by
setup.
Quickly 3 times Setup is running but
there are errors.
Not at all None Check the power
supply!
NOTE
The command open is not echoed on the screen.