Chapter 5 ________________________________________________________________ Operation
VAISALA______________________________________________________________________ 139
0312-061
Figure 121 Output of the Logshow Command
The header information shows the variable name
(TAMeasQMH101_1m:Avg and RHMeasQMH101_1m:Avg).
The log entry information includes the time tag, that is, date and time of
the entry, the status, and the value of the logged measurement or
calculation.
Controlling Logging
Logging is automatically on if it has been defined in the setup and if it
has not been stopped. Logging is automatically stopped when the log
file is retrieved with MAWS Terminal. When download is
accomplished, logging is activated again automatically.
When a sensor is replaced, stopping is not necessary if some invalid log
items can be tolerated. Alternatively, instead of stopping logging, you
Table 18 Log Entry Status
Status Indicator Status Description
-I----- Invalid Value may be outside the set
scale; that is, the set
climatological limits or step
change validation.
-I--N- Invalid; not available No measurements done yet.
V----- Valid (normal) Measurement or calculated
value available normally.