User's Guide ______________________________________________________________________
176 __________________________________________________________________M210630EN-B
2. Check that the gauge is still level. It is surprisingly easy for an
apparently immovable gauge to become tilted as a result of small
ground movements, vandalism, or just an inquisitive finger.
3. Clean the spoon from dust and dirt once or twice a year to ensure
precise measuring.
Periodic Maintenance of QMR102
To ensure reliable and accurate measurements, Vaisala recommends
that the following checks be carried out at each visit to the rain gauge.
1. Inspect the funnel and filter for any damage or blockage. At certain
times of the year leaves may have accumulated in the funnel, dirt
and dust can also block the filter preventing or reducing the flow
rate to a slow drip into the buckets beneath. The leaves can easily
be removed from the funnel and the filter can be cleaned by
removing the end cap from the filter tube. Remove the filter
material carefully, clean and replace the filter and cap.
2. Check that the gauge is still level. It is surprisingly easy for an
apparently immovable gauge to become tilted as a result of small
ground movements, vandalism or just an inquisitive finger.
3. Remove and clean any dirt from the bucket.
4. There will be times when the rain gauge will not log or will be
disconnected from the logger. In such cases, it is a good idea to
check the balance arm of the bucket for stiffness. The easiest way
to do this in the field is to try to balance the bucket in its center
position. It should be very difficult, if not impossible, to achieve
this. If the bucket balances easily then examine the bucket closely
for any dirt or wear on the pivot pin and bucket tubes.
NOTE
If the gauge is connected to the AWS logger and the logger is
operating, avoid tipping the cup assembly.