3. MAWS does not receive commands entered in MAWS Terminal.
a. Check the terminal cable connection and that you have the
correct terminal cable (QMZ101) in use.
b. The terminal connection is not open.
Type open and press ENTER. Note that the command must be
typed exactly correct before it can be executed and that the
command is not echoed on the screen.
c. The port settings are not synchronous.
Synchronize PC COM port and MAWS COM port settings.
4. Has someone made any software or hardware changes to the
MAWS system prior to malfunction? If so, could those changes
have an effect on the operation? You can capture the content shown
in MAWS Terminal, refer to section Recording Terminal
Connection Text on page 189.
a. When you have loaded a new setup:
- Make sure you have the original setup and the new setup
saved as a .dtg file.
- Reload the original setup and verify that the system starts
and runs with the original setup.
- Check the new setup once again with MAWS Lizard,
reload it, and verify that the system starts and runs.
b. When you have installed new hardware:
- Disconnect the new hardware.
- Reload the original setup and verify that the system starts
and runs.
- Check the new setup once again with MAWS Lizard.
- Connect the new hardware.
- Reload the new setup and verify that the system starts and
runs.
5. Sensor(s) are not working properly.
a. Are there one or multiple malfunctioning sensors? Multiple
simultaneous sensor malfunctions in the same logger often
indicate a damaged logger.