User's Guide ______________________________________________________________________
190 __________________________________________________________________M210630EN-B
When you no longer need the capture file, you can delete it from your
PC. The capture file is called MAWS_Terminal.Log and it is saved in the
Default capture text directory you have defined on the Directories
tab in the Preferences window.
In problem situations, give the following commands: battery, errors,
spset, SYSINFO, and warnings. When Capture all is selected, the
results are saved into a file for future use.
Opening Service Connection
Through MAWS
The command interface of the modem or an intelligent sensor can be
accessed through MAWS, for example, to send the AT commands
manually. To control the modem or sensor directly, open the service
connection to MAWS, and, for example, when the device is connected
to the DSU232’s first communication port at the module place MOD1,
type open DSU232_0_0. To terminate this operation, type close. While
the direct connection to the modem or sensor is open, any automatic
operation through the connected port is blocked. Typical parameters for
the open command are presented in Table 25 on page 190. Information
concerning the correct connector can be obtained in MAWS Lizard
under I/O Connections in the Equipment view.
Table 25 Parameters for the Open Command
Connector in MAWS Lizard Parameter
COM0 COM0
COM1 COM1
DSU232 (MOD1/1)
DSU232_0_0
1
1. With DSU232 and DSI486 modules, the number between the underline
characters stands for the module place, that is, MOD1 or MOD2, and the
last number for the channel on that particular module.
DSU232 (MOD1/2) DSU232_0_1
DSU232 (MOD2/1) DSU232_1_0
DSU232 (MOD2/2) DSU232_1_1
DSI486 (MOD1/1) DSI486_0_0
DSI486 (MOD1/2)
DSI486_0_1
2
2. With the DSI486 module, the RS-232 connection is possible only to the
channel B on the module, and thus the last number is 1.
DSI486 (MOD2/1) DSI486_1_0
DSI486 (MOD2/2)
DSI486_1_1
2