Vaisala HUMICAP MMT310 Wartungshandbuch Seite 96

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 123
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 95
172 173
HMT363 Humidity and Temperature Transmitter
For general use
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360
3
A
PRICE
1
Transmitter t
yp
e HMT363 3
2
Parameters
RH+T A
$2,160
RH+T+Td+a+Tw+x D
$2,710
3
Display No display 1
Display on transmitter cover 2
$120
4
Signal Output 2 analog output channels (Ch1 + Ch2) 4... 20 m
A
2
Parameter and scaling for No analog output A
analog output (Ch1 & Ch2) RH (0... 100%RH) B B
T (choose range in next section) C C
Td (-40...100°C) (-40...212°F) HH
a (0...500g/m3) (0...218.5gr/ft3) JJ
Tw (0...100°C) (+32...+212°F) KK
x (0...500g/kg d.a) (0...3500gr/lb) LL
Special: Define quantity for: CH1:___________
_
CH2:________________ XX
Define scale for: CH1:___________
_
CH2:________________
NOTE:
5
- Td, a, Tw and x are only avalable with parameter selection D Ch1
6
- If only one analog output has been chosen, choose A for Ch2 Ch2
7
Analog output range -20...+80°C (-4...+176°F) D
for temperature -20...+120°C (-4...+248°F) E
-40...+80°C (-40...+176°F) F
- If no temperature output is desired, cho
o
-40...+120°C (-40...+248°F) G
0...+100°C (+32...+ 212°F) H
Special X
8
Output units Metric 1
Non-metric 2
9
Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A
Conduit fitting NPT1/2" (for wire conduits) B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm C
10
Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2
Factory Mutual (USA) 4
CSA (Canada) 5
TIIS (Japan) 7
11
User's guide No manual A
English B
12 Probe and cable length 2 m cable max 80°C 1
5 m cable max 80°C 2
$150
10 m cable max 80°C 3
$300
2 m cable max 120°C B $220
5 m cable max 120°C C
$360
10 m cable max 120°C D
$540
13
Sensor type HUMICAP 180 1
HUMICAP 180L2 2
HUMICAP 180R 5
14
Reserved for future option A
15 Sensor protection PPS plastic grid & stainless steel netting (recommended cho
i
DRW0101281SP 1
PPS plastic grid DRW0101276SP 2
Sintered stainless steel filter HM47280SP 3
Stainless steel grid filter HM47453SP 4
16
Probe installation accessories None
0
Duct installation kit B
$80
TOTAL
Selections in bold are included in the prices of the basic versions. QTY
Selections in italic are available at an extra price. TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
RH = Relative Humidit
y
a = Absolute Humidity g/m3 HMT360 3A22BCD2A4BB5A1B
T = Temperature x = Mixing Ratio g/Kg
Td = Dewpoint Temper
a
Tw = Wet Bulb Temperature
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description Order Code: PRICE
Stahl Zener Barrier (Stahl # 9001/51-280-091-141) $190/channel
(active barrier that requires active input)
Vyniker enclosure $90 each
(enclosure holds 2 barriers)
210665
210664
Transmitter unit
HMT364 Humidity and Temperature Transmitter
For high pressurized processes
1 2 3 4 5 6 7 8 9 10111213141516
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360
4
A
PRICE
1
Transmitter t
yp
eHMT364 4
2
Parameters
RH+T A
$3,270
RH+T+Td+a+Tw+x D
$3,810
3
Display No display 1
Display on transmitter cover 2
$120
4
Signal Output 2 analog output channels (Ch1 + Ch
2
4... 20 m
A
2
Parameter and scaling for No analog output A
analog output (Ch1 & Ch2) RH (0... 100%RH) B B
T (choose range in next section) C C
Td (-40...100°C)
(-40...212°F)
HH
a (0...500g/m3)
(0...218.5gr/ft3)
JJ
Tw (0...100°C)
(+32...+212°F)
KK
x (0...500g/kg d.a)
(0...3500gr/lb)
LL
Special: Define quantity for: CH1:___________
_
CH2:________________
XX
Define scale for: CH1:___________
_
CH2:________________
NOTE:
5
- Td, a, Tw and x are only avalable with parameter selection D Ch1
6
- If only one analog output has been chosen, choose A for Ch2 Ch2
7
Analog output range -20...+80°C
(-4...+176°F)
D
for temperature
-20...+120°C
(-4...+248°F)
E
-40...+80°C
(-40...+176°F)
F
- If no temperature output is desired, cho
o
-40...+120°C
(-40...+248°F)
G
0...+100°C
(+32...+ 212°F)
H
-20...+180°C
(-4...+356°F)
J
-40...+180 °C
(-40...+356°F)
K
0...+180°C
(+32...+356°F)
L
Special X
8
Output units Metric 1
Non-metric 2
9
Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A
Conduit fitting NPT1/2"
(for wire conduits)
B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm C
10
Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2
Factory Mutual (USA) 4
CSA (Canada) 5
TIIS (Japan) 7
11
User's guide No manual A
English B
12 Probe and cable length
2 m cable E
5 m cable F $160
10 m cable G $370
13
Sensor type HUMICAP 180 1
HUMICAP 180L2 2
HUMICAP 180R 5
14
A
15
Sensor protection PPS plastic grid & stainless steel netting (recommended choi
c
DRW0101281SP
1
PPS plastic grid
DRW0101276SP
2
Sintered stainless steel filter
HM47280SP 3
Stainless steel grid filter
HM47453SP
4
16
Probe installation accessories None
0
Fitting body M22x1.5 male K
Fitting body NPT 1/2" male G
TOTAL
Selections in bold are included in the prices of the basic versions. QTY
Selections in italic are available at an extra price. TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
RH = Relative Humidity a = Absolute Humidity g/m3
HMT360 4A2 2BCD2A4BE5A3G
T = Temperature x = Mixing Ratio g/Kg
Td = Dewpoint Temper
a
Tw = Wet Bulb Temperature
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description Order Code: PRICE
Stahl Zener Barrier (Stahl # 9001/51-280-091-141) $190/channel
(active barrier that requires active input)
Vyniker enclosure $90 each
(enclosure holds 2 barriers)
210665
210664
Transmitter unit
Seitenansicht 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 122 123

Kommentare zu diesen Handbüchern

Keine Kommentare