Vaisala WINDCAP WS425 Betriebsanweisung Seite 173

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 221
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 172
Chapter 5 _________________________________________________________________ Operation
aC! Start Concurrent Measurement
This command starts concurrent measurement. WMT700 does not
return measurement data after this command. It sends a response
that indicates when the measurement result can be retrieved using
the aD0! command and the number of parameters.
aC!
where
a
=
Single-digit WMT700 address that corresponds to the
first character of the address value
C
=
Start concurrent measurement command
!
=
Terminates the command
The response is the following:
atttnn<CR><LF>
where
a
=
Single-digit WMT700 address that corresponds to the
first character of the address value
ttt
=
Period of time, in seconds, after which WMT700 has
the measurement ready
nn
=
Number of measurement values WMT700 calculates
and returns as a response to one or more subsequent
aD0! commands
<CR><LF>
=
Terminates the response
Example of the command and response:
1C!
100205<CR><LF>
Interpretation of the example message:
- Time after which the measurement is ready: 2 seconds
- Number of returned measurement values: 5
To fetch the measurement results, use the aD0! command.
VAISALA _______________________________________________________________________ 171
Seitenansicht 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 220 221

Kommentare zu diesen Handbüchern

Keine Kommentare