User's Guide ______________________________________________________________________
Table 42 Required Parameters for WS425 Analog
Output Operation Mode
Description of How to Emulate WS425
Set 1 for voltage output and 625 for
frequency output for similar operation as
Set 0.017895 for compatibility with WS425
voltage output.
Set 11.18 for compatibility with WS425
Set 0.0027855 for compatibility with
WS425 potentiometer output.
1 = Voltage
2 = Frequency
3 = Disabled
Analog output mode for AOUT1.
Set 1 for WS425 voltage output
compatibility.
2 for WS425 frequency output
5 = Voltage
6 = Potentiometer
Analog output mode for AOUT2.
Set 6 WS425 potentiometer output
compatibility.
Offset for AOUT1 and AOUT2.
Set output offset to 0.
For configuration instructions, see section Configuration on page
110.
140 __________________________________________________________________ M211095EN-E