Chapter 4 ________________________________________________________________ Operation
VAISALA ______________________________________________________________________ 103
Issue the command without parameters and press Enter to display
current recording parameters.
Example:
>dsel tdf x
Tdf x
>dsel
Tdf x
>
View Recorded Data
If the device is provided with the optional display, the graphical display
shows the data of the selected quantities, one at a time. See section
Graphic History on page 64 for details about graphical display.
DIR
Use the serial line and issue the DIR command to check the available
files.
Without the data logger module, the transmitter records five files (five
observation periods) for each selected quantity. The data logger raises the
number of recorded files to six for each quantity. Thus, the total amount
of the files varies between 5 and 18. See Table 11 on page 65.
Select, for example, two quantities (T and Tdf). The last column
illustrates the number of data points that has been stored in the file.