PTB 200 1 (28)
Digital Barometers
SSD/Operating Manual 24th February 1993 PTB200-O0284-1.1
PTB 200 DIGITAL BAROMETERS
1 PRODUCT DESCRIPTION 2
2 INSTALLATION 3
2.1 Mounting 3
2.2 Grounding 4
2.3 Power connections 5
2.4 Serial output mode connections 6
2.5 Pulse output mode connections 7
2.6 Pressure connections 8
2.7 Multiple barometers on one RS 232C bus 9
3 SERIAL COMMANDS 10
3.1 General 10
3.2 Configuration commands 11
3.3 Operating commands 19
4 ADJUSTMENT AND CALIBRATION 22
4.1 Offset and gain adjustment 23
4.2 Multipoint adjustment 24
5 TECHNICAL DATA 26
Appendix 1 Commands
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1 - PTB 200 DIGITAL BAROMETERS

PTB 200 1 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1PTB 200 DIGITAL BAROMETERS1 PRODUCT DESCRIPTION 22 INSTALLATIO

Seite 2 - SERIAL COMMANDS

PTB 200 9 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.12.7 Multiple transmitters on one RS 232C busIt is possible to

Seite 3

PTB 200 10 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.13 SERIAL COMMANDS3.1 GeneralWhen delivered from factory the b

Seite 4

PTB 200 11 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1The PTB 200 barometers have three sending modes: STOP, RUN an

Seite 5 - BRASS DISKS

PTB 200 12 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1Examples:>SERI<cr>1200 E 7 1>SERI 9600 E 7 1

Seite 6

PTB 200 13 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1The basic definition consists of the current and new format:&

Seite 7 - RS 232C TTL TTL INVERT

PTB 200 14 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1UNIT Setting the pressure unitUNIT x<cr>wherex hPa*, kP

Seite 8 - PULSE TRIG

PTB 200 15 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1FILT Setting the filter parametersFILT xxx yyyy<cr>wh

Seite 9

PTB 200 16 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1SMODE Setting the sending modeSMODE xxxx<cr> STOP and R

Seite 10 - COMPUTER

PTB 200 17 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1ADDR Setting the barometer address (for POLL mode only)ADDR&l

Seite 11

PTB 200 18 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1SLEEP Setting and resetting the sleep modeSLEEP ON<cr>

Seite 12

PTB200 Digital BarometerAppendix 11994-08-16 1SERIAL COMMANDSFunction Command Commentserial bus settings SERIecho on/off ECHOoutput format FORMpressu

Seite 13

PTB 200 19 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.13.3 Operating commandsR Starting the measurement outputR<c

Seite 14

PTB 200 20 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1Example of outputting the current settings:>INTV<cr>

Seite 15

PTB 200 21 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1RESET Resetting the barometerRESET<cr>resets the barome

Seite 16

PTB 200 22 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.14 ADJUSTMENT AND CALIBRATIONThe PTB 200 barometers can be adj

Seite 17 - POLL mode only

PTB 200 23 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1The following pressure adjustments are possible:• offset adju

Seite 18 - (STOP and RUN modes only)

PTB 200 24 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1Example of an offset and gain adjustment:>LP<cr>Ref1

Seite 19 - -0.056 hPa

PTB 200 25 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1First precalibrate the barometer at up to eight pressure leve

Seite 20

PTB 200 26 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.15 TECHNICAL DATAOPERATING RANGEPressure range 600 ... 1100 hP

Seite 21 - (POLL mode only

PTB 200 27 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1GENERAL CHARACTERISTICS (factory settings*)Supply voltage 10

Seite 22

PTB 200 28 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1Dimensions in mm (inches)27.5 (1.08)120 (4.72)65 (2.56)Ø 6.5

Seite 23 - MEMORY JUMPER

PTB 200 2 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.11 PRODUCT DESCRIPTIONThe PTB 200 A and PTB 201 A are fully com

Seite 24 - • offset/gain adjustment

PTB200 Digital BarometerAppendix 11994-08-16 1SERIAL COMMANDSFunction Command Commentserial bus settings SERIecho on/off ECHOoutput format FORMpressu

Seite 25

PTB 200 3 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.12 INSTALLATION2.1 MountingThe dimensions and recommended mount

Seite 26

PTB 200 4 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.12.2 GroundingA single electrical cable with a screen and five

Seite 27

PTB 200 5 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.12.3 Power connectionsTwo wires, one for supply voltage and ano

Seite 28

PTB 200 6 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.12.4 Serial output mode connectionsThe serial communication can

Seite 29 - Dimensions in mm (inches)

PTB 200 7 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.12.5 Pulse output mode connections (software version 1.05 or hi

Seite 30

PTB 200 8 (28)Digital BarometersSSD/Operating Manual 24th February 1993 PTB200-O0284-1.1The pulse frequency is about 4.5 kHz at baud rate 9600. The pu