User’s Guide ______________________________________________________________________
202 __________________________________________________________________M210785EN-E
0711-122
Figure 103 Calculations View: Configuring Timer Option
There are several configuration options in the Configuration
frame on the right:
Option Description
Repeat times Defines how many timed events will be created
Scale Indicates whether the timed events are tied to
absolute time or whether they are relative and
only the interval is meaningful
Time Zone Specifies whether UTC or local time is used to
calculate the timed events, if the scale selected
is Absolute
Priority Defines the priority of the timer. Typically,
Normal or Slow are the most suitable options.
A Fast timer should be used only in time-
critical actions
Sync time [ms] Defines the moment that the timed events are
tied to (as in Timers view)
Trig interval time [ms] Specifies the interval between timed events
(as in Timers view)