Vaisala Humicap HMD60Y Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
HMD60U/Y Transmitters
U301en-1.1 Operating Manual
1997-07-31 1
1. PRODUCT DESCRIPTION
The HMD60 transmitters are duct mounted two-wire transmitters for the
measurement of humidity (HMD60U) and for the measurement of humidity
and temperature (HMD60Y).
The HMD60U/Y transmitters are easy to install and maintain: the electronics
can be disconnected without dismantling the installation. One point calibration
is easily performed with the HMI41 indicator and the calibration cable
19116ZZ.
Both transmitter types incorporate the HUMICAP
®
180 humidity sensor which
uses an operating principle based on changes in the capacitance of a thin
polymer film as it absorbs water molecules. The HMD60Y transmitters
measure temperature with the reliable Pt 1000 sensor.