Seitenansicht 9
HMD70U/Y Transmitters
Operating Manual U303en-1.1
6 1997-07-31
3.4.1 Connection to an AC supply
The HMD70U/Y transmitters can also be connected to an AC supply without
an external rectifier. However, when more than one transmitter is connected to
one AC transformer, a common loop is formed and there is an increased risk
of a short-circuit. To avoid this, use a separate floating supply for each
transmitter (see Figure 3.4.1.1). However, if several transmitters have to share
one transformer, the phase () must always be connected to Us connector in
each transmitter (see Figure 3.4.1.1).
HMD70U/Y transmitter
Controller
VAC
VAC
Us
GND
signal
RH/T
GND
Us
RH/T
signal
HMD70U/Y transmitter
HMD70U/Y transmitter
HMD70U/Y transmitter
Controller
shared
common line
VAC
GND
GND
Us
Us
RH/T
RH/T
signal
signal
Figure 3.4.1.1 Connection to an AC supply