Vaisala HydroMet Betriebsanweisung Seite 144

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 160
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 143
User's Guide ______________________________________________________________________
142 __________________________________________________________________M210784EN-E
Isolated RS-485 Module DSI485
The isolated RS-485 communication module can be configured either
for a 2-wire line or for a 4-wire line when the receive and transmit lines
are separated. If the module is configured for a 2-wire line, the
transmitter is enabled only during the transmission. Normally, the 2-
wire connection is used to connect several devices to the same
communication line. The 4-wire mode is the default mode.
1006-100
Figure 64 Isolated RS-485 Module Wiring Diagram
NOTE
In 2-wire mode, only T+ and T- pins are used.
Seitenansicht 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 159 160

Kommentare zu diesen Handbüchern

Keine Kommentare