Vaisala HMT360Series Spezifikationen Seite 120

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 141
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 119
HMT 368 Intrinsically Safe Humidity and Temperature Transmitter
Model with Probe for Pipeline Installations
BACK to
Price List
Table of
Contents
BACK to
Catalog
Table of
Contents
-17-
PRICE
Humidity and Temperature Transmitter
HMT 368 A
Transmitter type
RH+T A
$2,825
RH+T+Td+a+Tw+x D
$3,325
Display on cover
no 1
yes 2
$105
Signal output
1 analog output (Ch1) 4... 20 mA 1
2 analog output (Ch1 + Ch2) 4... 20 mA 2
$230
LonWorks field bus (no analog opt
s)
TP78 3
$285
Analog output signals
No analog output A A
for Ch1 and Ch2
RH (0... 100%RH) B B
Temperature (choose range-next section) C C
Td (-40...100°C)
(-40...212°F)
HH
a (0...500g/m3)
(0...218.5gr/ft3)
JJ
Tw (0...100°C)
(+32...+212°F)
KK
NOTE:
x (0...500g/kg d.a)
(0...3500gr/lb)
LL
- Choose A for both channels with LonWorks field bus
- Td, a, Tw and x are only available with transmitter type D
Ch1
- If only one analog output has been chosen, choose A for
C
Ch2
Analog output range
-20...+80°C
(-4...+176°F)
D
for temperature
-20...+120°C
(-4...+248°F)
E
-40...+80°C
(-40...+176°F)
F
-40...+120°C
(-40...+248°F)
G
0...+100°C
(+32...+ 212°F)
H
-20...+180°C
(-4...+356°F)
J
-40...+180 °C
(-40...+356°F)
K
0...+180 °C
(+32...+356°F)
L
Other ( specify ) X
Output units
metric 1
non-metric 2
Cable bushings
cable gland Pg11 A
conduit fitting NPT1/2" (for wire conduits) B
Ex certification and issuer
CENELEC 76/117/EEC (VTT) 1
Operating manual language
no manual A
english B
Probe type and cable length
2 m (6 ft) 178mm probe, max +180 °C L
5 m (16 ft) 178mm probe, max +180 °C M
$150
10 m (33 ft) 178mm probe, max +180 °C N
$350
2 m (6 ft) 400mm probe, max +180 °C P
$75
5 m (16 ft) 400mm probe, max +180 °C Q
$225
10 m (33 ft) 400mm probe, max +180 °C R
$425
Humidity sensor type
general purpose*
HUMICAP 180
1
special sensor for high solvent concentrations HUMICAP 180L
2
special sensor for hydrogen environments
HUMICAP 180J
3
Sensor protection in probe
PPS plastic grid & stainless steel netting
16720HM
1
$30
PPS plastic grid
16526
2
$25
sintered stainless steel filter*
16452
3
$50
PPS plastic grid with PTFE membrane filter
17230HM
5
$25
Installation kit
no kit
A
ball valve set for installation into pipeline E
$65
Ex certification and issuer
CENELEC 76/117/EEC (VTT) 1
*recommmended choice TOTAL
RH = Relative Humidity a = Absolute Humidity g/ m 3 QTY
T = Temperature x = Mixing Ratio g/ Kg TOTAL VALUE
Td = Dewpoint Temperature Tw = Wet Bulb Temperature
Selections in italic are available at extra cost.
Selections in bold text are su
pp
lied free of char
g
e.
Example of order code with typical settings:
HMT 368 A
12BCD1A1B
L1A3A1
Transmitter unit
transmitter unit probe
Probe
BACK to
Tech Data
Sheet
Seitenansicht 119